Description

Description: Setting method: Start value <stop value (program automatically determines working mode is heating/humidifying mode) Setting method: Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode) Heating/cooling mode setting Setting mode: setting (starting temperature): Press and hold the �� button to start the temperature flashing. Use ���� key to set the starting temperature value. Setting (stop temperature): Press and hold the �� button to stop the temperature flashing. Use ���� to set the stop temperature value.

Heating use case: control the water heater, heat to 65 �� C to stop, the temperature drops back to 50 �� C and start heating again The first step: heating mode, starting temperature <stop temperature Step 2: Press and hold the �� button to start the temperature flashing. Use ���� to set the starting temperature to 50 ��C. Step 3: Press and hold the �� button to stop the temperature flashing. Set the stop temperature to 65 ��C with ���� keys, and the setting is completed! Refrigeration use case: use in the farm, the fan is ventilated to 26 �� C to stop, the temperature is raised to 30 �� C and the ventilation is started again. The first step: cooling mode, starting temperature > stop temperature Step 2: Press and hold the �� button to start the temperature flashing. Use ���� to set the starting temperature to 30 ��C. The third step: long press the �� button to stop the temperature flashing, set the stop temperature to 26 ��C by ����, the setting is completed!

Humidification/Dehumidification Mode Settings: Setting (start humidity): Press and hold �� key to start the humidity value flashing. Set the humidity value by �� �� key. Set [Stop Humidity]: Press and hold �� key to stop the humidity value flashing, and set the humidity to stop by �� �� key value.

Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification. Setup steps: ??Step 1: Press and hold the �� button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH. ??Step 2: Press and hold the �� button for 3 seconds to stop the humidity value flashing. Set the value to 80% RH. After the setting is completed, the button will be operated for 5 seconds without returning to the normal display state.

Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification

Package Included: 1PCS*SHT2000 AC 110-220V / DC 12-72V Temperature & Humidity Hygrometer Thermostat Controller Sensor

#DIYMORE #DIY #Temprerature #Temp #Controller #Control #Thermostat #Sensor #Digital #Switch# #Humidity #Probe #Measuring #Levelling #Home #Living #Hygrometer

Product type: Laboratory Thermostatic Devices

Warranty

On-time delivery guarantee
We provide customs clearance and certification
We provide closing documents at the time of payment
Protection of the transaction (payment in installments)

SHT2000 Digital Thermostat Hygrometer Temperature Humidity Controller 10A With Probe AC 110-220V / DC 12-72V

5-9 pc.
$15.98
10-49 pc.
$13.59
50 pc.
$11.99

Colour: Like the picture

Quantity
$15.98
1,000pcs available
Products: 0 pcs
$0
Delivery:
...
The total order cost will be different

Description

Description: Setting method: Start value <stop value (program automatically determines working mode is heating/humidifying mode) Setting method: Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode) Heating/cooling mode setting Setting mode: setting (starting temperature): Press and hold the �� button to start the temperature flashing. Use ���� key to set the starting temperature value. Setting (stop temperature): Press and hold the �� button to stop the temperature flashing. Use ���� to set the stop temperature value.

Heating use case: control the water heater, heat to 65 �� C to stop, the temperature drops back to 50 �� C and start heating again The first step: heating mode, starting temperature <stop temperature Step 2: Press and hold the �� button to start the temperature flashing. Use ���� to set the starting temperature to 50 ��C. Step 3: Press and hold the �� button to stop the temperature flashing. Set the stop temperature to 65 ��C with ���� keys, and the setting is completed! Refrigeration use case: use in the farm, the fan is ventilated to 26 �� C to stop, the temperature is raised to 30 �� C and the ventilation is started again. The first step: cooling mode, starting temperature > stop temperature Step 2: Press and hold the �� button to start the temperature flashing. Use ���� to set the starting temperature to 30 ��C. The third step: long press the �� button to stop the temperature flashing, set the stop temperature to 26 ��C by ����, the setting is completed!

Humidification/Dehumidification Mode Settings: Setting (start humidity): Press and hold �� key to start the humidity value flashing. Set the humidity value by �� �� key. Set [Stop Humidity]: Press and hold �� key to stop the humidity value flashing, and set the humidity to stop by �� �� key value.

Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification. Setup steps: ??Step 1: Press and hold the �� button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH. ??Step 2: Press and hold the �� button for 3 seconds to stop the humidity value flashing. Set the value to 80% RH. After the setting is completed, the button will be operated for 5 seconds without returning to the normal display state.

Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification

Package Included: 1PCS*SHT2000 AC 110-220V / DC 12-72V Temperature & Humidity Hygrometer Thermostat Controller Sensor